SNEO001 EMS Sculpting Machine

【Product name】 EMS Sculpting Machine
【handle configuration】 Single handle
【working   voltage】 110v/220v/50/60Hz
【Electromagnetic wave energy】 0-3.5T
【pulse shape】 Biphasic wave
【RF frequency】 3M
【pulse】 300μs(Microsecond)
【weight】 12KG
【size】 34.5×33.5×26(cm)
【Aviation  box  size】 60x46x34.5(cm)
【Patent No】 202110601087.8

SNEO001 EM Sculpt (home version) Machine

PRINCIPLE:
This machine uses high-intensity focused electromagnetic wave EMS technology to stimulate muscles, so as to achieve muscle fiber proliferation, and at the same time stimulate fat decomposition, to achieve non-invasive, painless and safe body shaping. The features of the instrument use high-intensity focused electromagnetic wave energy to stimulate super strong muscle contraction. During the treatment
process, it provides a series of different muscle contraction modes to stimulate muscle movement, so as to easily achieve the purpose of self-cultivation and shaping.

OPERATION:
①Main switch: press once, the switch indicator light is on, and it is powered on at this time;
②Long press the on key on the control screen to start / stop;
③Click “-” + “for energy adjustment.

SNEO001 EM Sculpt (home version) Machine

SNEO001 EM Sculpt (home version) Machine

SNEO001 EM Sculpt (home version) Machine

Advantages over other instruments:
1. The whole course of treatment is non-radiation, non-invasive, and has no recovery period.
2. Promoting fat decomposition while stimulating muscle growth.

Instrument principle: muscle gain and lipolysis instrument, using HIFEM (High-Intensity Focused
Electromagnetic Field) technology, through stimulation of nerves, the autologous muscles are continuously expanded and contracted, and extreme training is carried out. The muscles can be deeply remodeled, that is, the growth of myofibrils.) and produce new collagen chains and muscle fibers (muscle hyperplasia), thereby training and increasing muscle density and volume. The 100% limit muscle contraction of HIFEM technology can trigger a large amount of lipolysis. Fatty acids are broken down from triglyceric acid and accumulated in large amounts in fat cells. Excessive fatty acid concentration can cause fat cells to undergo apoptosis and be excreted from the body through normal metabolism within a few weeks. Therefore, the treatment can strengthen and increase muscles while achieving the effect of reducing fat.

Precautions
Before using E-M sculpt
1、Don’t be full, at least one hour after meals;
2. Before operation, please remove any metal jewelry you wear;
3. Before starting the operation, first touch the probe vertically to the skin, then turn on the main unit switch, adjust the operation mode energy to the lowest, and then increase the energy sequentially according to the user’s skin bearing capacity;
4. It’s forbidden to eat or drink during the operation, and try to eat after one hour after the operation.

After using E-M sculpt
1、Users should replenish water in time;
2、Don’t overeat, reasonably arrange diet and sleep;
3、Be sure to strengthen moisturizing and sunscreen after use;
4、Don’t eat spicy and irritating food;
5、After operating this project, please don’t take a hot spring or sauna for three days;

Contraindications
1、People with wounds on the skin, or avoid the wounds;
2、Heart disease patients (e.g. arrhythmia), especially those with a pacemaker;
3、Cancer patients;
4、Patients with infectious diseases;

Maintenance and repair
1. Maintenance
2.Daily inspection
Managers must regularly inspect and control instruments and components. Whether the power socket is reliably connected to the ground. Before use,check whether the power cord of it is damaged,and stop using the instrument if it is damaged.
3.Cleaning
Periodically cleaning the equipment to ensure the sanitation and good operation of it. You can wipe the outside of the device with a damp cloth when it’s powered off, using soapy water or a neutral detergent.
4. Fuse replacement
When replacing the fuse, in order to prevent electric shock, you must turn off the power and unplug the power plug.
5.Repair
After purchasing the machine, you need to keep the warranty card and send it to the manufacturer or agent to have the warranty effect From the date of purchase (by receipt), the company’s product quality is guaranteed for one year free of charge(Warranty with the purchase receipt and
warranty card:)After the warranty period has expired, please contact the manufacturer directly to provide professional after-sales service. To repair this machine, you must contact the company’s business department or dealer, and do not repair it without authorization. If you open the package without consent, the company may not provide warranty. Common troubleshooting method.
5、Pregnant women, lactation and menstruation;
6、Those who have undergone major surgery, patients with diabetes;
7、Those with any metal in the body;
8、People with cerebrovascular diseases (stroke patients)

Common troubleshooting method:
Failure phenomenon Causes Exclusion and resolution
Equipment not
working
The power plug is not inserted into the socket

The power switch is not on

Failure of power fuse

check  power

check the power switch

replace the fuse

Handle not working The working head has been damaged

The interface on the back of it is not installed correctly

replace working head

reinstall

Storage and transportation management

Storage:
The instrument should be stored in the original packaging box, placed in a well-ventilated room, the packaging box should be high, the ambient temperature is -10℃~40℃, the relative humidity is not more than 93%, and it is not allowed to be placed in harmful gas. Surrounding flammable, explosive materials and corrosive gases.

Transportation:
The instrument in the packaged condition is suitable for road, railway, aviation and waterway transportation. During loading and unloading and transportation, it should be protected from severe vibration and shock, and should not be exposed to moisture, and cannot be mixed with flammable and corrosive substances. The specific requirements are as specified in the order contract.

Chongqing Vision Star S&T Co., Ltd. is specialized in manufaturing and selling beauty equipment for business, aesthetic clinic and salon, and we are offering professional esthetician devices, including hair removal and skin treatment laser, IPL, DPL, OPT , HIFU, EMS, fat freezing, radio frequency, skin cleaning, skin analysis machine, etc. We have gotten rich experiences, owned complete product range and mature production line in beauty industry, built solid sales network throughout Europe, America, Asia, Africa and other countries. Our products have earned high praise for good quality and price in the international market. You can choose different payment methods, get free Logo customization service, one-to-one sales assistance, and 1-3 years quality assurance from our company. We are devoted to establishing win-win cooperation with you, and providing one-stop solution for your business. Please send inquiry or just contact us if you are interested in SNEO001 EMS Sculpting Machine or other products.